C1s-Depleted Human Serum (catalog number NB-DS005) is a complement research reagent from Novatein Biosciences. Size: 0.5 ml/vial.
Handling: human-derived material. Use normal precautions for handling human blood products.
C1s depleted serum (C1s-Dpl) is normal human serum depleted of C1s by immunoaffinity chromatography. The product is tested for the absence of C1s by functional assays for classical pathway activity and for C1s protein by double immunodiffusion. C1s-Dpl is certified to possess a functional alternative pathway for complement activation. In serum C1s is present in its proenzyme form. C1s enzyme is the activated form of C1s proenzyme. C1s proenzyme is an inactive zymogen until C1 is activated. C1r is activated when C1 binds to and is activated by antibodies bound to antigens (immune complexes) yielding C1r enzyme, the first protease that initiates the cascade. C1r enzyme in the C1 complex activates C1s proenzyme generating C1s enzyme. A functional classical pathway can be reconstituted by addition of purified C1s proenzyme (31 µg/mL) to the C1s-Dpl indicating that all other complement components necessary for classical pathway activation are present and active.
Activation of C1s proenzyme in the C1 complex is regulated indirectly by C1- INH. C1r self- activation, and subsequent C1s activation, is controlled by a weak association of C1r with C1 esterase inhibitor (C1-INH) when it is in the C1 complex. Once activated, C1s enzyme is rapidly inactivated by C1-INH.
C1s-Dpl is supplied as a clear, straw-colored liquid containing all proteins of normal human serum except complement component C1s.
The depleted serum is tested for remaining classical pathway activity (CH50 assay) by hemolytic assays using antibody-sensitized sheep erythrocytes and for alternative pathway function (AP50 assay) using rabbit erythrocytes. The depleted serum is reconstituted with 31 µg/mL C1s proenzyme and retested to verify that a functional classical pathway is restored. The Certificate of Analysis provided with each lot gives a description of the assays and specific titers for the depleted and reconstituted sera compared to normal human serum.
The unit of classical pathway activity is the CH50. The classical pathway activity is reported as the standard CH50 value for C1s-Dpl + C1s proenzyme added equivalent to 31 µg C1s/mL in the undiluted serum. The CH50 activity is determined as the amount of reconstituted serum needed to lyse 50% of 1 x 108 EA cells (antibody-sensitized sheep erythrocytes) when incubated for 60 min at 37 oC in a total volume of 1.5mL GVB++. Normal human serum is used as standard. See the Certificate of Analysis for lot specific titer values. Alternative pathway titers are performed to document that this pathway of complement activation is fully functional in C1s-Dpl. Lectin pathway activity is not tested.
C1s-Dpl is used to assay C1s hemolytic activity in samples and to supply an alternative pathway activating system that is incapable of activating the classical pathway of complement.
The source is human serum, therefore precautions appropriate for handling any blood-derived product must be used even though the source was shown by certified tests to be negative for HBsAg and for antibodies to HCV, HIV-1 and HIV-II.
Hazard Code: B MSDS available upon request.